Beyond the Cracks
Understanding How Buildings Change Over Time
A look at how structural engineers assess aging buildings, identify structural and non-structural concerns, and determine how buildings change over time, using Glencoe High School as an example.
Quiet Changes as Buildings Age
Glencoe High School is one of the four original high schools in Hillsboro and is over 40 years old. Its name originates from the farming community of Glencoe, an old settlement located north of Hillsboro along the road connecting Hillsboro and North Plains. Like many long-standing buildings, Glencoe has changed over time. Some of those changes are easy to see, like the recent remodel and new additions. Others happen quietly, within the walls, floors, and beams, and only become noticeable years later.
What Happens to Buildings Over Time?
Observational Site Visit
Photo: Crushing and distortion of existing gypsum wall board at corridor walls below existing precast concrete beam elements.
This image, taken by an MCE staff member during the site walk-throug, shows cracking and distortion along the upper right side of the wall. To most people, cracks in a building suggest the structure itself may be failing, making it natural to assume the walls, or even the building, are in trouble. However, that isn't always the case. So, what do engineers see and determine during observational site visits?
During the walk-through, MCE staff documented the cracking and distortion with photographs for further analysis. By reviewing the original school drawings, the location of the cracking, and the materials used in the building, they determined that the issue was with the wall surface rather than the overall structure. While the image may look unsettling, engineers look beyond the surface. By comparing observed conditions with the original designs, they can determine whether the building can still safely support the loads it was designed for, despite the visible damage.
Photo: Beams have rotated at their ends above existing concrete columns and corbels due to long-term beam deflection, known as creep.
This image shows a different kind of change that happens in older structures. Here, two concrete beams meet above a column, and a gap has gradually opened between them. MCE's assessment found that the beams had rotated slightly at their ends, tilting away from each other over time. This movement is caused by a slow process called creep.
Beyond the Surface
What Happens Next?
More Than a School
Topics
Condition Assessment, Education Facilities, Foundation Cracks and Settlement: When Is Repair Needed?
Photos
Widening gap at end of concrete beam